High-quality, Gel-filled, pH Probe
The Milwaukee pH Probe is a high-quality pH probe that is filled with gel and designed for use with select monitors and controllers. The probe features a double-junction design that reduces the risk of clogging, and a spherical glass tip that provides the largest possible surface area for faster and more accurate results. The resin body is tough and can withstand accidental knocks, while also protecting the glass sensing bulb. Additionally, the probe comes with a 6.6-foot cable that provides increased flexibility when measuring.
Specifications:
- Body: Polypropylene Resin
- Reference: Double, Ag/AgCl
- Junction: Cloth, Single
- Electrolyte: Gel
- pH Range: 0-14 pH
- Tip Shape: Sphere
- Diameter: 0.5 inches
- Dimensions: 4.7 inches / 6.4 inches
- Operating Temperature: -5 to 70°C (23 to 158°F)
- Cable length: 6.6 feet
- Connection: BNC
Use and Care
The pH meters typically start performing poorly because of problems with the probe. The glass sensing bulb and the reference junction are two parts of the pH probe that cause problems.
- Sensing Bulb –The sensitivity of the glass bulb in pH probes decreases with use and will eventually lead to failure.
- Reference Junction –The reference junction is a tiny aperture that enables the pH meter to compare the sample with a reference. The reading is produced by evaluating the electrical disparity between the sample and the reference. If the junction hole is obstructed, the pH probe will cease functioning. To prolong the life of your pH electrode, you can follow the tips below.
Storage
It is essential to keep the pH probe hydrated to maintain its sensitivity. If the probe is stored in a dry environment for a long time, it can damage its sensitivity and clog the junction hole. To avoid this, it is recommended to store the probe in pH probe storage solution or pH calibration buffers. Do not store the probe in tap or DI water, as it can damage its sensitivity. The best way to store the probe is to fill the probe’s cap with storage solution or calibration buffer and tighten the cap to prevent leakage. It is also recommended to store the electrode upright to further reduce the potential for leakage.
Cleaning
Regularly soaking your electrode in a cleaning solution can prevent residue buildup and blockage of the junction, especially when dealing with samples containing organic material.
Calibration
The sensitivity of pH-sensing bulbs decreases over time. Therefore, it is essential to calibrate your PRO pH meter regularly. Additionally, calibrate it after cleaning or storing it for an extended period.
WARRANTY
CoralVue, Inc. and Milwaukee hereby guarantee this product tobe free from defects in material and workmanship for a period of:
- 1-year
Warranty is activated on the date of purchase.
This Standard Limited Warranty applies and is limited as follows:
- To the product only as long as it remains in the possession of the original purchaser.
- To the product that has not been subject to accident, misuse or abuse.
- To the product that has not been modified, altered, defaced, or had repairs made or attempted byother than CoralVue, Inc.
- That CoralVue be immediately notified in writing within ten (10) days of first knowledge of defectby owner or his agent.
- That CoralVue, Inc. shall be given first opportunity to make any repairs, replacements orcorrections to the defective construction within a reasonable period of time.
- Under no circumstances shall CoralVue and/or the Manufacturer be liable by virtue of this warrantyor otherwise for damage to any person or property whatsoever for any special, indirect, secondary orconsequential damages of any nature however arising out of the use or inability to use because ofthe product defect.
Click here to learn more.
PRODUCT SUPPORT
To submit a warranty claim, please visit our CoralVue SupportPortal.






Reviews
There are no reviews yet.